Module codes of AED404 / AED416 Devices and the Corresponding Digital I/O Channel Numbers

Digital I/O Channel Numbering Rules:

  • The Digital I/O channel numbering system is based on module codes. In a synchronized multichannel AE diagnostic system formed from AED404 and/or AED416 devices, all Digital I/O channels have different channel number.

  • All AED416 devices have 8 Digital I/O channels. For any of these devices the starting Digital I/O channel number is: (ModuleCodeAED416 – 1)*16 + 1.

  • All AED404 devices have 3 Digital I/O channels. For any of these devices the starting Digital I/O channel number is: (ModuleCodeAED404 – 1)*4 + 1.

 

 